Simultaneous fluoride and arsenic removal from groundwater by using aluminium sacrificial anode
The simultaneous removal of fluoride and arsenic in groundwater collected from three deep wells situated in Western part of Romania was carried out by electrocoagulation (EC) with aluminium sacrificial anode. The current density was of 156, 480 and 780 A/m2 , respectively and the electrolysis time 6...
Elmentve itt :
Szerzők: | |
---|---|
Testületi szerző: | |
Dokumentumtípus: | Könyv része |
Megjelent: |
2016
|
Sorozat: | Proceedings of the International Symposium on Analytical and Environmental Problems
22 |
Kulcsszavak: | Talajvíz - szennyeződés - mérés |
Online Access: | http://acta.bibl.u-szeged.hu/56069 |
Tartalmi kivonat: | The simultaneous removal of fluoride and arsenic in groundwater collected from three deep wells situated in Western part of Romania was carried out by electrocoagulation (EC) with aluminium sacrificial anode. The current density was of 156, 480 and 780 A/m2 , respectively and the electrolysis time 60 min. The removal efficiency of fluoride and arsenic was determined based on their residual concentration. Also, the specific energy consumption was calculated and it was in the range of 0.14 - 1.40 kWh/m3. |
---|---|
Terjedelem/Fizikai jellemzők: | 176-179 |
ISBN: | 978-963-306-507-5 |