Respiratory effects on the reproducibility of cardiovascular autonomic parameters

The aim of this study was to assess the influence of breathing pattern on the reproducibility of the most commonly used heart rate and blood pressure variability parameters and baroreflex indices. 5-5 min ECG and blood pressure recordings were made and repeated for 10 healthy volunteers in supine re...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Zöllei Éva
Csillik Andrea
Rabi S
Gingl Zoltán
Rudas László
Dokumentumtípus: Cikk
Megjelent: 2007
Sorozat:CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING 27 No. 4
Tárgyszavak:
doi:10.1111/j.1475-097X.2007.00736.x

mtmt:1448266
Online Access:http://publicatio.bibl.u-szeged.hu/30192
LEADER 02648nab a2200265 i 4500
001 publ30192
005 20240424094608.0
008 240424s2007 hu o 000 eng d
022 |a 1475-0961 
024 7 |a 10.1111/j.1475-097X.2007.00736.x  |2 doi 
024 7 |a 1448266  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a eng 
100 1 |a Zöllei Éva 
245 1 0 |a Respiratory effects on the reproducibility of cardiovascular autonomic parameters  |h [elektronikus dokumentum] /  |c  Zöllei Éva 
260 |c 2007 
300 |a 205-210 
490 0 |a CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING  |v 27 No. 4 
520 3 |a The aim of this study was to assess the influence of breathing pattern on the reproducibility of the most commonly used heart rate and blood pressure variability parameters and baroreflex indices. 5-5 min ECG and blood pressure recordings were made and repeated for 10 healthy volunteers in supine rest on 10 consecutive days during spontaneous and 6 min(-1) patterned breathing. We investigated the following parameters: mean RR interval (RRI); the standard deviation of RR intervals (SDRR); the root mean square of successive differences in RRI (RMSSD); the percentage of RRIs which differed by 50% from the proceeding RRI (PNN50); mean systolic arterial pressure (SAP); the standard deviation of SAP (SAP SD); mean mean arterial pressure (MAP); mean diastolic blood pressure (DAP) and baroreflex indices from spontaneous sequence method (upBRS and downBRS) and from cross spectral analysis (LF alpha, HF alpha). To assess reproducibility for each parameter within- and between-subject variability values were calculated and the ratio of within- and between-subject variability was assessed. In addition, we calculated intraclass correlation coefficient (ICC). Compared to spontaneous respiration during 6 min(-1) patterned breathing the heart rate and blood pressure variability increased; upBRS, LF alpha and HF alpha increased, downBRS did not change. However, ICC showed good reproducibility for most parameters, which did not improve further with controlled breathing. In conclusion, respiration had a strong influence on the most widely used cardiovascular autonomic parameters. The controlling of breathing did not result in consistent improvement in their reproducibility. 
650 4 |a Klinikai orvostan 
700 0 1 |a Csillik Andrea  |e aut 
700 0 1 |a Rabi S  |e aut 
700 0 1 |a Gingl Zoltán  |e aut 
700 0 1 |a Rudas László  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/30192/1/ClinPhysioFunctImaging-2007-Zollei-Respiratoryeffectsonthereproducibilityofcardiovascularautonomic.pdf  |z Dokumentum-elérés