Zero and Minimal Fluoroscopic Approaches During Ablation of Supraventricular Tachycardias A Systematic Review and Meta-Analysis /

Catheter ablations for cardiac arrhythmias are conventionally performed under fluoroscopic guidance. To guide these procedures, zero/minimal fluoroscopy (Z/MF) approaches have become available, using three-dimensional electroanatomical mapping systems. Our aim was to conduct a meta-analysis comparin...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Debreceni Dorottya
Jánosi Kristóf
Vámos Máté
Komócsi András
Simor Tamás
Kupó Péter
Dokumentumtípus: Cikk
Megjelent: 2022
Sorozat:FRONTIERS IN CARDIOVASCULAR MEDICINE 9
Tárgyszavak:
doi:10.3389/fcvm.2022.856145

mtmt:32800047
Online Access:http://publicatio.bibl.u-szeged.hu/24674
LEADER 02818nab a2200277 i 4500
001 publ24674
005 20220708124720.0
008 220708s2022 hu o 0|| Angol d
022 |a 2297-055X 
024 7 |a 10.3389/fcvm.2022.856145  |2 doi 
024 7 |a 32800047  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a Angol 
100 1 |a Debreceni Dorottya 
245 1 0 |a Zero and Minimal Fluoroscopic Approaches During Ablation of Supraventricular Tachycardias   |h [elektronikus dokumentum] :  |b A Systematic Review and Meta-Analysis /  |c  Debreceni Dorottya 
260 |c 2022 
300 |a Terjedelem: 10-Azonosító: 856145 
490 0 |a FRONTIERS IN CARDIOVASCULAR MEDICINE  |v 9 
520 3 |a Catheter ablations for cardiac arrhythmias are conventionally performed under fluoroscopic guidance. To guide these procedures, zero/minimal fluoroscopy (Z/MF) approaches have become available, using three-dimensional electroanatomical mapping systems. Our aim was to conduct a meta-analysis comparing these two different methods for the treatment of paroxysmal supraventricular tachycardia (SVT).Electronic databases were searched and systematically reviewed for studies comparing procedural parameters and outcomes of conventional, fluoroscopy-guided vs. Z/MF approaches in patients undergoing electrophysiology (EP) procedures for SVTs. The random-effects model was used to derive mean difference (MD) and risk ratios (RRs) with 95% confidence interval (CI).Twenty-four studies involving 9,074 patients met our inclusion criteria. There was no difference between the groups in terms of acute success rate (RR = 1.00, 95% CI, 0.99-1.01; p = 0.97) and long-term success rate (RR: 1.01, 95% CI, 1.00-1.03; p = 0.13). Compared to the conventional method, zero-and-minimal fluoroscopy (Z/MF) ablation significantly reduced fluoroscopic time [MD: -1.58 min (95% CI, -2.21 to -0.96 min; p < 0.01)] and ablation time [MD: -25.23 s (95% CI: -42.04 to -8.43 s; p < 0.01)]. No difference could be detected between the two groups in terms of the procedure time [MD: 3.06 min (95% CI: -0.97 to 7.08; p = 0.14)] and the number of ablation applications [MD: 0.13 (95% CI: -0.86 to 1.11; p = 0.80)]. The complication rate was 1.59% in the entire study population and did not differ among the groups (RR: 0.68, 95% CI: 0.45-1.05; p = 0.08).The Z/MF approach for the catheter ablation of SVTs is a feasible method that reduces radiation exposure and ablation time without compromising the acute and long-term success or complication rates. 
650 4 |a Klinikai orvostan 
700 0 1 |a Jánosi Kristóf  |e aut 
700 0 1 |a Vámos Máté  |e aut 
700 0 1 |a Komócsi András  |e aut 
700 0 1 |a Simor Tamás  |e aut 
700 0 1 |a Kupó Péter  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/24674/1/Debreceni.pdf  |z Dokumentum-elérés