Navigáció alkalmazása az implantológiában összefoglaló áttekintés a pontossági adatok alapján /

Our objective was to assess the literature regarding the accuracy of the different static guided systems. After applying electronic literature search we found 661 articles. After reviewing 139 articles, the authors chose 52 articles for full-text evaluation. 24 studies involved accuracy measurements...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Barrak Ibrahim Ádám
Varga Endre, ifj
Piffkó József
Dokumentumtípus: Cikk
Megjelent: 2016
Sorozat:FOGORVOSI SZEMLE 109 No. 2
mtmt:3109550
Online Access:http://publicatio.bibl.u-szeged.hu/16544
LEADER 02290nab a2200217 i 4500
001 publ16544
005 20190830100734.0
008 190830s2016 hu o 0|| zxx d
022 |a 0015-5314 
024 7 |a 3109550  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a zxx 
100 1 |a Barrak Ibrahim Ádám 
245 1 0 |a Navigáció alkalmazása az implantológiában   |h [elektronikus dokumentum] :  |b összefoglaló áttekintés a pontossági adatok alapján /  |c  Barrak Ibrahim Ádám 
260 |c 2016 
300 |a 61-68 
490 0 |a FOGORVOSI SZEMLE  |v 109 No. 2 
520 3 |a Our objective was to assess the literature regarding the accuracy of the different static guided systems. After applying electronic literature search we found 661 articles. After reviewing 139 articles, the authors chose 52 articles for full-text evaluation. 24 studies involved accuracy measurements. Fourteen of our selected references were clinical and ten of them were in vitro (modell or cadaver). Variance-analysis (Tukey's post-hoc test; p < 0.05) was conducted to summarize the selected publications. Regarding 2819 results the average mean error at the entry point was 0.98 mm. At the level of the apex the average deviation was 1.29 mm while the mean of the angular deviation was 3,96 degrees. Significant difference could be observed between the two methods of implant placement (partially and fully guided sequence) in terms of deviation at the entry point, apex and angular deviation. Different levels of quality and quantity of evidence were available for assessing the accuracy of the different computer-assisted implant placement. The rapidly evolving field of digital dentistry and the new developments will further improve the accuracy of guided implant placement. In the interest of being able to draw dependable conclusions and for the further evaluation of the parameters used for accuracy measurements, randomized, controlled single or multi-centered clinical trials are necessary. 
700 0 1 |a Varga Endre, ifj.  |e aut 
700 0 1 |a Piffkó József  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/16544/1/NavigacioalkalmazasaazimplantologiabanOsszefoglaloattekintesapontossagiadatokalapjanNavigationinimplantologyAccuracyassessmentregardingtheliterature.pdf  |z Dokumentum-elérés