Volumetric but Not Time Capnography Detects Ventilation/Perfusion Mismatch in Injured Rabbit Lung

Whereas time capnography (Tcap) is routinely displayed during mechanical ventilation, the volumetric representation (Vcap) is seldom used. We compared the diagnostic value of indices derived from Tcap and Vcap following ventilation to perfusion ratio (<(V)over dot>/<(Q)over dot>) mismatc...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Tolnai József
Fodor Gergely
Babik Barna
Rocha Andre Dos Santos
Bayat Sam
Peták Ferenc
Habre Walid
Dokumentumtípus: Cikk
Megjelent: 2018
Sorozat:FRONTIERS IN PHYSIOLOGY 9
doi:10.3389/fphys.2018.01805

mtmt:30367428
Online Access:http://publicatio.bibl.u-szeged.hu/14298
LEADER 03261nab a2200277 i 4500
001 publ14298
005 20190110150307.0
008 190110s2018 hu o 0|| zxx d
022 |a 1664-042X 
024 7 |a 10.3389/fphys.2018.01805  |2 doi 
024 7 |a 30367428  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a zxx 
100 1 |a Tolnai József 
245 1 0 |a Volumetric but Not Time Capnography Detects Ventilation/Perfusion Mismatch in Injured Rabbit Lung  |h [elektronikus dokumentum] /  |c  Tolnai József 
260 |c 2018 
300 |a 11 p.-10.3389/fphys.2018.01805 
490 0 |a FRONTIERS IN PHYSIOLOGY  |v 9 
520 3 |a Whereas time capnography (Tcap) is routinely displayed during mechanical ventilation, the volumetric representation (Vcap) is seldom used. We compared the diagnostic value of indices derived from Tcap and Vcap following ventilation to perfusion ratio (<(V)over dot>/<(Q)over dot>) mismatch subsequent to experimentally induced acute respiratory distress syndrome (ARDS), and alveolar recruitment by elevating the positive end-expiratory pressure (PEEP). Lung injury was induced by iv lipopolysaccharide, whole lung lavage and injurious ventilation in anesthetized, mechanically ventilated rabbits (n = 26). Mainstream Tcap and Vcap were performed to assess normalized phase 2 (Sn2(T), Sn2(V)) and phase 3 slopes (Sn3(T), Sn3(V)) in the time and volumetric domains. Vcap was also used to estimate Enghoff's physiological dead space (VDE). Lung oxygenation index (PaO2/FiO(2)) and intrapulmonary shunt (Qs/Qt) were derived from arterial and central venous blood gas samples. All measurements were made under baseline conditions, and, following lung injury, under moderate (6 cmH(2)O) and high PEEP levels (9 cmH(2)O). Lung injury deteriorated the PaO2/FiO(2) (baseline vs. injured 466 +/- 10.2 [95% confidence interval] vs. 77.3 +/- 17.1 mmHg, p < 0.05) and compromised all mechanical parameters significantly, whereas Tcap parameters exhibited contradictory or inconsistent changes. Conversely, Vcap indices exhibited consistent changes and provided excellent diagnostic value in detecting lung-function deterioration subsequent to lung injury [area under the receiver operating characteristic (ROC) curve of 1.0 +/- 0.0, 0.87 +/- 0.22 and 0.86 +/- 0.22 for VDE, Sn3(V) and Sn3(V)/Sn2(V), respectively]. Elevated PEEP increased PaO2/FiO(2) and decreased Qs/Qt, which was reflected only in the Vcap slope ratio (Sn3(V)/Sn2(V), p < 0.05). Our findings demonstrate the limited value of Tcap to detect ventilation to perfusion ratio (<(V)over dot>/<(Q)over dot>) mismatch, following severe lung injury. Conversely, indices derived from Vcap proved to be sensitive for detecting lung volume loss and alveolar recruitment. Therefore, promotion of Vcap is of paramount importance as a real-time, non-invasive, bedside monitoring modality to detect the development of and to follow-up the progression of lung injury in a model of ARDS. 
700 0 1 |a Fodor Gergely  |e aut 
700 0 1 |a Babik Barna  |e aut 
700 0 1 |a Rocha Andre Dos Santos  |e aut 
700 0 1 |a Bayat Sam  |e aut 
700 0 1 |a Peták Ferenc  |e aut 
700 0 1 |a Habre Walid  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/14298/1/fphys-09-018051.pdf  |z Dokumentum-elérés