Radiation dose to the nodal regions during prone versus supine breast irradiation

BACKGROUND: Prone positioning for breast radiotherapy is preferable when the aim is a reduction of the dose to the ipsilateral lung or the heart in certain left-sided cases. MATERIALS AND METHODS: In 100 breast cancer cases awaiting postoperative whole-breast radiotherapy, conformal radiotherapy pl...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Csenki Melinda
Újhidy Dóra
Cserháti Adrienn
Kahán Zsuzsanna
Varga Zoltán
Dokumentumtípus: Cikk
Megjelent: Dove Medical Press, Ltd. 2014
Sorozat:THERAPEUTICS AND CLINICAL RISK MANAGEMENT 10
doi:10.2147/TCRM.S59483

mtmt:2597207
Online Access:http://publicatio.bibl.u-szeged.hu/11871
LEADER 02389nab a2200253 i 4500
001 publ11871
005 20200219153834.0
008 170830s2014 hu o 0|| zxx d
022 |a 1176-6336 
024 7 |a 10.2147/TCRM.S59483  |2 doi 
024 7 |a 2597207  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a zxx 
100 1 |a Csenki Melinda 
245 1 0 |a Radiation dose to the nodal regions during prone versus supine breast irradiation  |h [elektronikus dokumentum] /  |c  Csenki Melinda 
260 |a Dove Medical Press, Ltd.  |c 2014 
300 |a 367-372 
490 0 |a THERAPEUTICS AND CLINICAL RISK MANAGEMENT  |v 10 
520 3 |a BACKGROUND: Prone positioning for breast radiotherapy is preferable when the aim is a reduction of the dose to the ipsilateral lung or the heart in certain left-sided cases. MATERIALS AND METHODS: In 100 breast cancer cases awaiting postoperative whole-breast radiotherapy, conformal radiotherapy plans were prospectively generated in both prone and supine positions. The axillary nodal region (levels I-III) and internal mammary (IM) lymph-node region in the upper three intercostal spaces were retrospectively contoured. The mean doses to the nodal regions and the volume receiving 25 Gy (V25Gy), V45Gy, and V47.5Gy were compared between the two treatment positions. RESULTS: In most cases, the doses to axillary levels I-III and the IM lymph nodes were inadequate, regardless of the treatment position. The nodal doses were significantly lower in the prone than in the supine position. The radiation doses to levels II-III and IM nodes were especially low. The V45Gy and V47.5Gy of the level I axillary lymph nodes were 54.6% and 40.2%, respectively, in the supine, and 3.0% and 1.7%, respectively, in the prone position. In the supine position, only 17 patients (17%) received a mean dose of 45 Gy to the axillary level I nodes. CONCLUSION: The radiation dose to the axillary and IM lymph nodes during breast radiotherapy is therapeutically insufficient in most cases, and is significantly lower in the prone position than in the supine position. 
700 0 1 |a Újhidy Dóra  |e aut 
700 0 1 |a Cserháti Adrienn  |e aut 
700 0 1 |a Kahán Zsuzsanna  |e aut 
700 0 1 |a Varga Zoltán  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/11871/1/TCRM_59483_the_radiation_dose_to_the_nodal_regions_during_prone_versus__052114_u.pdf  |z Dokumentum-elérés