Analysis of pesticides in food products using SFE-SFC-MSMS

The use of an online system combining Supercritical Fluid Extraction (SFE) and Supercritical Fluid Chromatography (SFC) with tandem Mass Spectrometry for the analysis of pesticide residues in food products is introduced in this study. In addition, SFE of organochlorine pesticides was performed for s...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerző: Baumgarten Sigrid
Dokumentumtípus: Cikk
Megjelent: WESSLING Nemzetközi Kutató és Oktató Központ Közhasznú Nonprofit Kft. Budapest 2016
Sorozat:Élelmiszervizsgálati közlemények 62 No. 4
Kulcsszavak:Élelmiszervizsgálat - módszer, Élelmiszerkémia - módszer, Növényvédőszerek - kémiai analízis - mérés, Élelmiszerbiztonság
Tárgyszavak:
Online Access:http://acta.bibl.u-szeged.hu/79113
LEADER 02079nab a2200229 i 4500
001 acta79113
005 20230826082029.0
008 230706s2016 hu o 0|| eng d
022 |a 0422-9576 
040 |a SZTE Egyetemi Kiadványok Repozitórium  |b hun 
041 |a eng 
100 1 |a Baumgarten Sigrid 
245 1 0 |a Analysis of pesticides in food products using SFE-SFC-MSMS  |h [elektronikus dokumentum] /  |c  Baumgarten Sigrid 
260 |a WESSLING Nemzetközi Kutató és Oktató Központ Közhasznú Nonprofit Kft.  |b Budapest  |c 2016 
300 |a 1292-1294 
490 0 |a Élelmiszervizsgálati közlemények  |v 62 No. 4 
520 3 |a The use of an online system combining Supercritical Fluid Extraction (SFE) and Supercritical Fluid Chromatography (SFC) with tandem Mass Spectrometry for the analysis of pesticide residues in food products is introduced in this study. In addition, SFE of organochlorine pesticides was performed for subsequent analysis by GC-MS/ MS. SFC was proven to be a powerful technique for the separation of a wide range of pesticides with different chemical structures, polarities and molecular weights. 100 pesticides were extracted from different food matrices and analyzed using the online SFE-SFC-MS/MS system. The entire process was characterized by good repeatability in the concentration range 1 to 10 ng/g. LOQs ranged from 0.1 to 10 μg/L The system was configured to enable automated switching to offline extraction to perform analysis with either SFC or GC-MS. Offline SFE and analysis by GC-MS of organochlorine pesticides was accomplished with good accuracy (recoveries between 80 and 125%) for the majority of analytes. 
650 4 |a Műszaki és technológiai tudományok 
650 4 |a Egyéb műszaki tudományok és technológiák 
650 4 |a Élelmiszer és italfélék 
695 |a Élelmiszervizsgálat - módszer, Élelmiszerkémia - módszer, Növényvédőszerek - kémiai analízis - mérés, Élelmiszerbiztonság 
856 4 0 |u http://acta.bibl.u-szeged.hu/79113/1/elelmiszervizsgalati_kozlemenyek_2016_04_1292-1294.pdf  |z Dokumentum-elérés