Development of targeted LC-MS/MS method for analysis of diclofenac and its main metabolites in rat liver perfusion solution obtained by new type of ex vivo perfusion system

Isolated perfused rat liver (IPRL) is used as ex vivo simulation for more accurate evaluation of pharmacokinetic parameters of target drugs, production of their metabolites and their excretion in the bile. Compared to in vivo systems, IPRL avoids the clearance of any other organ and permits the cont...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Dweny Aya
Körmöczi Tímea
Kovács Orsolya
Samavati Reza
Gáspár Róbert
Berkecz Róbert
Testületi szerző: International Symposium on Analytical and Environmental Problems (24.) (2018) (Szeged)
Dokumentumtípus: Könyv része
Megjelent: 2018
Sorozat:Proceedings of the International Symposium on Analytical and Environmental Problems 24
Kulcsszavak:Gyógyszerkémia - előadáskivonat
Online Access:http://acta.bibl.u-szeged.hu/56348
LEADER 03458naa a2200265 i 4500
001 acta56348
005 20220808155025.0
008 190107s2018 hu o 1|| zxx d
020 |a 978-963-306-623-2 
040 |a SZTE Egyetemi Kiadványok Repozitórium  |b hun 
041 |a zxx 
100 1 |a Dweny Aya 
245 1 0 |a Development of targeted LC-MS/MS method for analysis of diclofenac and its main metabolites in rat liver perfusion solution obtained by new type of ex vivo perfusion system  |h [elektronikus dokumentum] /  |c  Dweny Aya 
260 |c 2018 
300 |a 280-281 
490 0 |a Proceedings of the International Symposium on Analytical and Environmental Problems  |v 24 
520 3 |a Isolated perfused rat liver (IPRL) is used as ex vivo simulation for more accurate evaluation of pharmacokinetic parameters of target drugs, production of their metabolites and their excretion in the bile. Compared to in vivo systems, IPRL avoids the clearance of any other organ and permits the control over the factors that may affect the hepatic metabolism, for example, the flow rate of the perfusate, pH, pressure, and concentration of chemicals. This simple experimental technique, unlike the cultured cells, keeps the intactness of the liver, in other words, cells other than hepatocytes, drug transporters' distribution, as well as enzymes, are still affecting the metabolism which gives a realistic picture [1-2]. The portal vein of the anesthetized rat was cannulated and the perfusion solution saturated with carbogen (95% O2 and 5% CO2) was pumped through it. The solution was directed through the transected abdominal vein to the waste. A cannula was inserted into the inferior vena cava through the right heart atrium through which the perfusate leaved the liver after the ligation of the abdominal vein. The isolated liver was then placed into the buffer vapour chamber of the recirculated perfusion system and the perfusate samples were collected during different time intervals. The main goal of our work was the development of targeted reversed-phase LC-MS/MS analytical method for the analysis of diclofenac (DF) and its main metabolites namely diclofenac-O-acyl glucuronide (Glu-DF) and 4-hydroxydiclofenac (4´OH-DF) in the perfusion solution of rat liver. We are planning to use diclofenac as a reference compound in the future investigation of metabolism of designer drugs. DF and its metabolites were extracted by the optimized liquid-liquid extraction procedure. LC separation was achieved by gradient elution of the mobile phase consisted of 0.1% formic acid in water and 0.1% of formic acid in acetonitrile on a Luna Phenyl-Hexyl column at 50˚ C with a run time of 10 minutes. The Agilent 1100 LC system was coupled to the triple quadrupole TSQ 7000 mass spectrometer. The appropriate transitions were monitored during the region of elution of each analyte. The linearity range of DF was between 100 ng/mL and 40 μg/mL. The related matrix effect, recovery and process efficiency were successfully evaluated. 
695 |a Gyógyszerkémia - előadáskivonat 
700 0 1 |a Körmöczi Tímea  |e aut 
700 0 1 |a Kovács Orsolya  |e aut 
700 0 1 |a Samavati Reza  |e aut 
700 0 1 |a Gáspár Róbert  |e aut 
700 0 1 |a Berkecz Róbert  |e aut 
710 |a International Symposium on Analytical and Environmental Problems (24.) (2018) (Szeged) 
856 4 0 |u http://acta.bibl.u-szeged.hu/56348/1/proceedings_of_isaep_2018_280-281.pdf  |z Dokumentum-elérés